Sungrow Installer Training
Get fully trained to install, commission, and maintain Sungrow solar inverter and battery storage systems to professional standards. This course covers everything from PV fundamentals and system design to grid compliance, troubleshooting, and preventive maintenance. Develop the hands-on technical skills that utilities, inspectors, and clients expect from a qualified Sungrow installer.
What you'll learn:
You will build a complete skill set for working with Sungrow inverter and battery storage systems from the ground up. The course starts with photovoltaic principles, inverter technology, and electrical safety, then moves into product selection, string sizing, and code-compliant system design. You will learn how to execute mechanical and electrical installation to manufacturer specifications, commission systems step by step, and configure grid protection parameters. Troubleshooting methods cover DC faults, AC faults, battery alarms, and communication failures. You will also develop preventive maintenance routines and use iSolarCloud to monitor and optimise system performance over time.
How you study in practice Sungrow Installer Training
How you practise Sungrow Installer Training
For businesses looking to train their team
With Dedika for businesses, the course includes exercises and examples tailored to your own business and the way your company needs.
Course content
8 Chapters • 38 LessonsDuration between 4 and 360 hours (you decide)
Chapter 1HideHide detailsSee detailsSolar Energy and Inverter Fundamentals
Solar Energy and Inverter Fundamentals
Lesson 1 • Grid Interaction Basics
Introduces how inverters synchronise with the utility grid and manage power flow. Prepares students for grid compliance topics covered in later chapters.
Lesson 2 • Photovoltaic Principles and Solar Resources
Covers how sunlight converts to DC electricity and how irradiance affects output. Establishes the physics basis needed for all subsequent system design decisions.
Lesson 3 • Safety Standards for PV Systems
Covers electrical hazards, arc flash, and lockout/tagout procedures specific to solar installations. Establishes the safety mindset required throughout the entire course.
Lesson 4 • Inverter Technology Overview
Explains inverter types, topologies, and conversion stages. Connects hardware knowledge to Sungrow product selection in later chapters.
Chapter 2HideHide detailsSee detailsSungrow Product Portfolio and Selection
Sungrow Product Portfolio and Selection
Lesson 1 • Product Selection Criteria
Applies load analysis, site constraints, and grid requirements to product choice. Reinforces decision-making skills used throughout installation and commissioning chapters.
Lesson 2 • Residential String Inverter Range
Details single-phase and three-phase residential inverters, power classes, and key features. Connects product specs to the PV fundamentals established in Chapter 1.
Lesson 3 • Battery Energy Storage Products
Introduces Sungrow hybrid inverters and battery modules for residential and commercial storage. Prepares students for storage system design covered in Chapter 5.
Lesson 4 • Commercial and Utility-Scale Inverters
Covers medium- and large-scale string and central inverter platforms and their application boundaries. Builds on inverter topology knowledge to guide commercial project selection.
Chapter 3HideHide detailsSee detailsSystem Design and Array Configuration
System Design and Array Configuration
Lesson 1 • Electrical BOS Design
Addresses DC and AC wiring, overcurrent protection, and disconnects for Sungrow systems. Ensures designs meet equipment manufacturer and electrical safety requirements.
Lesson 2 • String Sizing and Voltage Calculations
Teaches Voc, Vmp, and temperature-corrected string voltage calculations for Sungrow MPPT inputs. Directly applies inverter spec knowledge from Chapter 2.
Lesson 3 • Design Documentation and Permitting
Covers single-line diagrams, site plans, and permit application packages. Prepares students to submit complete documentation before physical installation begins.
Lesson 4 • Energy Yield Estimation
Uses simulation tools to predict annual generation and validate design assumptions. Provides the performance baseline referenced during commissioning and monitoring.
Lesson 5 • Array Layout and Shading Analysis
Covers roof orientation, tilt optimisation, and shading impact on energy yield. Connects irradiance concepts from Chapter 1 to real site layout decisions.
Chapter 4HideHide detailsSee detailsMechanical Installation of Sungrow Inverters
Mechanical Installation of Sungrow Inverters
Lesson 1 • DC Array Wiring and Connection
Details MC4 connector assembly, string wiring, and DC input termination at the inverter. Builds on BOS design from Chapter 3 with hands-on wiring procedures.
Lesson 2 • Communication and Monitoring Wiring
Installs RS485, Ethernet, and CT sensor wiring for Sungrow monitoring systems. Prepares the physical communication layer for commissioning in Chapter 5.
Lesson 3 • Site Assessment and Pre-Installation Planning
Evaluates structural capacity, clearances, and environmental conditions before installation. Prevents costly rework by identifying site issues during the planning phase.
Lesson 4 • AC Output Wiring and Grid Connection
Covers AC terminal connections, neutral and earth wiring, and utility interconnection points. Ensures correct phase sequencing and safe grid tie-in procedures.
Lesson 5 • Mounting and Enclosure Installation
Covers wall-mount, floor-mount, and outdoor enclosure installation for Sungrow inverter models. Applies manufacturer torque specs and weatherproofing requirements.
Chapter 5HideHide detailsSee detailsCommissioning Sungrow Systems
Commissioning Sungrow Systems
Lesson 1 • Pre-Commissioning Safety Checks
Performs insulation resistance, polarity, and continuity tests before energising the system. Prevents equipment damage and ensures personnel safety during first power-up.
Lesson 2 • iSolarCloud Monitoring Setup
Registers the system on Sungrow's iSolarCloud platform and verifies live data reporting. Enables remote monitoring and fault detection covered in Chapter 7.
Lesson 3 • Inverter Startup and Initial Configuration
Guides through Sungrow inverter startup sequence and basic parameter entry via the display. Establishes the operating baseline for all subsequent configuration steps.
Lesson 4 • Battery Storage Commissioning
Covers hybrid inverter pairing, battery module initialisation, and operating mode selection. Builds on storage product knowledge from Chapter 2.
Lesson 5 • Grid Protection Parameter Setup
Configures voltage, frequency, and reconnection thresholds to meet local grid requirements. Directly applies grid interaction knowledge from Chapter 1.
Chapter 6HideHide detailsSee detailsGrid Compliance and Power Quality
Grid Compliance and Power Quality
Lesson 1 • Voltage and Frequency Ride-Through
Sets ride-through curves for low-voltage, high-voltage, and frequency disturbance events. Ensures the system remains connected during grid disturbances as required by grid codes.
Lesson 2 • Reactive Power and Power Factor Control
Explains Q(U) and cos-phi control modes and their configuration in Sungrow inverters. Connects grid interaction fundamentals from Chapter 1 to utility compliance requirements.
Lesson 3 • Active Power Curtailment and Ramp Rates
Configures export limits, dynamic curtailment, and ramp-rate controls for grid stability. Applies commissioning parameter skills from Chapter 5 to advanced grid functions.
Lesson 4 • Harmonic Distortion and EMC
Addresses total harmonic distortion limits and electromagnetic compatibility for Sungrow inverters. Ensures power quality compliance required by utility interconnection agreements.
Lesson 5 • Utility Inspection and Compliance Documentation
Prepares commissioning reports, parameter printouts, and test records for utility submission. Completes the compliance workflow started in the design and commissioning chapters.
Chapter 7HideHide detailsSee detailsTroubleshooting and Fault Diagnosis
Troubleshooting and Fault Diagnosis
Lesson 1 • Communication and Monitoring Faults
Resolves RS485, Ethernet, and iSolarCloud data reporting failures. Ensures monitoring integrity required for performance guarantees and remote diagnostics.
Lesson 2 • Battery Storage Fault Diagnosis
Covers BMS alarms, cell imbalance, and communication faults in Sungrow storage systems. Extends commissioning knowledge from Chapter 5 to post-installation fault resolution.
Lesson 3 • AC-Side and Grid Fault Diagnosis
Diagnoses grid overvoltage, undervoltage, frequency, and isolation faults on the AC side. Applies grid compliance knowledge from Chapter 6 to real fault scenarios.
Lesson 4 • DC-Side Fault Diagnosis
Identifies string open-circuit, earth fault, and MPPT imbalance faults using test instruments. Builds on array wiring knowledge from Chapter 4 to locate root causes.
Lesson 5 • Fault Code Interpretation
Decodes Sungrow inverter fault and warning codes from the display and iSolarCloud. Provides the diagnostic vocabulary needed for all subsequent troubleshooting sections.
Chapter 8HideHide detailsSee detailsPreventive Maintenance and System Optimisation
Preventive Maintenance and System Optimisation
Lesson 1 • Performance Analysis and Yield Optimisation
Uses iSolarCloud data to identify underperformance and implement corrective actions. Closes the loop between design yield estimates from Chapter 3 and actual system output.
Lesson 2 • PV Array Inspection and Cleaning
Details module soiling assessment, cleaning methods, and connector inspection procedures. Directly impacts energy yield and prevents degradation-related faults.
Lesson 3 • Battery Storage Maintenance
Covers battery capacity testing, cell balancing verification, and thermal system checks. Extends battery commissioning knowledge to long-term health management.
Lesson 4 • Inverter and Electrical Component Inspection
Covers thermal imaging, connection torque checks, and capacitor health assessment. Applies fault diagnosis skills from Chapter 7 to proactive condition monitoring.
Lesson 5 • Maintenance Planning and Scheduling
Establishes maintenance intervals, task lists, and documentation standards for Sungrow systems. Provides the organisational framework for all subsequent maintenance activities.
Your valid completion certificate
This course is for you:
Electricians: ready to add solar installation to their service offerings.
Solar technicians: working with other brands who want Sungrow-specific expertise.
HVAC contractors: expanding into renewable energy systems for existing clients.
Career changers: entering the clean energy trades from unrelated technical backgrounds.
General contractors: managing solar subcontractors and needing deeper product knowledge.
Recent trade school graduates: seeking a specialised credential to stand out when hiring.
What our students say
Your lessons are perfect. I purchased the one-year package and finally have the opportunity to follow various topics of interest without needing to change platforms... I'm grateful for everything you do, I've already recommended you to other people...

I like how the lessons are straight to the point and how I can change chapters and skip content I don't need.

I like the content and the way videos are presented and transcribed, which speeds up the process!

The platform is fast and simple to use. The diversity of content and complementary videos really help with learning.

Top upskilling courses
FAQ
Who is Dedika?
Is the certificate valid in Australia?
Are the courses free?
What is the course workload?
What are the courses like?
How do the courses work?
What is the duration of the courses?
What is the cost or price of the courses?
What is an EAD or online course and how does it work?
PDF Course