Split Air Conditioning Servicing Course
Master every skill needed to service, clean, and maintain split air conditioning systems from the ground up. You'll work through safety protocols, hands-on cleaning procedures, refrigerant handling, and electrical diagnostics with real-world precision. This course prepares you to deliver professional-grade AC maintenance that keeps systems running efficiently and clients coming back.
What your team will master:
You will learn how split AC systems work, how to safely shut them down, and how to clean every component inside and out. The course covers refrigerant leak detection, pressure testing, and proper recovery procedures that meet environmental regulations. You will develop electrical diagnostic skills to test motors, capacitors, and control boards with confidence. Preventive maintenance scheduling, performance benchmarking, and professional service reporting are also included. By the end, you will be equipped to handle real service calls, troubleshoot common faults, and build lasting client relationships.
How your team learns in practice Split Air Conditioning Servicing Course
How your team practises Split Air Conditioning Servicing Course
Professionals from these companies study at Dedika









Course content
8 Chapters • 41 LessonsDuration between 4 and 360 hours (you decide)
Chapter 1HideHide detailsSee detailsSafety Practices and Protective Equipment
Safety Practices and Protective Equipment
Lesson 1 • Waste Disposal and Environmental Compliance
Explains proper disposal of dirty water, chemical waste, and recovered refrigerant. Compliance with environmental regulations protects technicians from liability.
Lesson 2 • Personal Protective Equipment Selection
Matches PPE type to specific hazards: chemical splashes, sharp fins, refrigerant exposure, and noise. Correct PPE selection reduces injury risk during cleaning operations.
Lesson 3 • Chemical Handling and Storage
Addresses coil cleaners, mould inhibitors, and refrigerant cylinders. Students read safety data sheets and store chemicals according to compatibility requirements.
Lesson 4 • Working at Height Safely
Covers ladder selection, scaffold use, and fall-arrest equipment for high-wall and rooftop units. Safe elevated work is required before students access outdoor condensers.
Lesson 5 • Electrical Safety Fundamentals
Covers shock hazards, safe voltage thresholds, and proper de-energisation procedures. Electrical safety underpins every maintenance task in subsequent chapters.
Chapter 2HideHide detailsSee detailsFundamentals of Split AC Systems
Fundamentals of Split AC Systems
Lesson 1 • Refrigerants and Their Properties
Introduces common refrigerant types, global warming potential, and phase-out schedules. Proper refrigerant knowledge prevents mishandling and regulatory violations.
Lesson 2 • Outdoor Unit Components
Covers condenser coil, compressor, fan motor, capacitors, and service valves. Students map each part to its function within the refrigeration cycle.
Lesson 3 • Split AC System Configurations
Distinguishes wall-mounted, cassette, ducted, and multi-split configurations. Knowing each type prepares students for varied real-world installation scenarios.
Lesson 4 • How Refrigeration Cycles Work
Covers the vapour-compression cycle: evaporation, compression, condensation, and expansion. Establishes the thermodynamic basis for all maintenance decisions made later.
Lesson 5 • Indoor Unit Components
Identifies evaporator coil, blower fan, air filter, drain pan, and control board. Component recognition is prerequisite to any cleaning or diagnostic task.
Chapter 3HideHide detailsSee detailsTools and Equipment for AC Maintenance
Tools and Equipment for AC Maintenance
Lesson 1 • Hand Tools and Fastener Removal
Covers screwdrivers, nut drivers, hex keys, and panel-removal techniques. Proper tool use prevents stripped fasteners and damaged plastic housings.
Lesson 2 • Tool Maintenance and Calibration
Establishes cleaning, storage, and calibration routines for all service tools. Well-maintained tools ensure accurate results and extend equipment service life.
Lesson 3 • Electrical and Diagnostic Instruments
Covers multimeters, clamp meters, thermometers, and manifold gauge sets. Accurate readings from these instruments guide every diagnostic conclusion.
Lesson 4 • Leak Detection Equipment
Introduces electronic leak detectors, UV dye kits, and nitrogen pressure testing. Leak detection skills are essential before and after any refrigerant-side work.
Lesson 5 • Cleaning Equipment and Accessories
Introduces pressure washers, coil-cleaning guns, fin combs, and vacuum systems. Each tool is matched to the specific surface or component it cleans.
Chapter 4HideHide detailsSee detailsIndoor Unit Cleaning Procedures
Indoor Unit Cleaning Procedures
Lesson 1 • Reassembly and Functional Verification
Reinstalls all panels, restores power, and verifies airflow, temperature drop, and drainage. Functional checks confirm the unit is safe and fully operational.
Lesson 2 • Blower Wheel and Fan Cleaning
Covers in-place and removed blower wheel degreasing to eliminate dust buildup. Clean blower wheels reduce noise, vibration, and energy consumption.
Lesson 3 • Evaporator Coil Cleaning
Applies foaming coil cleaner, agitation, and rinse techniques to remove biofilm and scale. Coil cleanliness directly determines cooling capacity and energy efficiency.
Lesson 4 • Pre-Cleaning Inspection and Setup
Covers unit shutdown, cover removal, and condition assessment before cleaning begins. Thorough inspection prevents damage and identifies faults requiring repair.
Lesson 5 • Drain Pan and Drain Line Service
Flushes drain pans, clears blockages, and applies biocide to prevent algae regrowth. Proper drainage prevents water damage and indoor air quality problems.
Lesson 6 • Air Filter Removal and Cleaning
Details filter removal, washing, drying, and reinstallation for mesh and electrostatic types. Clean filters restore rated airflow and reduce blower motor strain.
Chapter 5HideHide detailsSee detailsOutdoor Unit Cleaning Procedures
Outdoor Unit Cleaning Procedures
Lesson 1 • Electrical Compartment Protection
Covers masking terminals, protecting control boards, and drying procedures before power restoration. Moisture ingress into electrical compartments causes failures and safety hazards.
Lesson 2 • Condenser Coil Cleaning Techniques
Applies inside-out rinsing, coil cleaner, and low-pressure washing to remove debris and scale. Restored condenser efficiency lowers discharge pressure and compressor load.
Lesson 3 • Cabinet and Base Pan Cleaning
Cleans cabinet panels, base pan, and drainage holes to prevent corrosion and standing water. A clean cabinet protects internal components from accelerated deterioration.
Lesson 4 • Outdoor Unit Shutdown and Isolation
Covers isolator switch operation, capacitor discharge, and refrigerant valve status checks. Safe isolation is mandatory before any contact with outdoor unit components.
Lesson 5 • Fan Blade and Motor Cleaning
Removes and cleans fan blades, checks motor bearings, and clears motor vents of debris. Clean fan assemblies maintain rated airflow across the condenser coil.
Chapter 6HideHide detailsSee detailsRefrigerant System Inspection and Handling
Refrigerant System Inspection and Handling
Lesson 1 • Identifying Refrigerant Leaks
Uses electronic detectors, UV dye, and soap solution to locate leaks at joints and valves. Early leak detection prevents refrigerant loss and compressor damage.
Lesson 2 • Pressure Testing After Repairs
Performs nitrogen pressure tests and standing pressure checks to confirm leak-free repairs. Pressure testing before recharging prevents refrigerant waste and repeat failures.
Lesson 3 • Refrigerant Recovery Procedures
Operates recovery machines to extract refrigerant into certified cylinders before opening systems. Proper recovery prevents atmospheric release and meets regulatory requirements.
Lesson 4 • Reading Manifold Gauges Accurately
Interprets high-side and low-side pressures against refrigerant pressure-temperature charts. Accurate gauge reading is the foundation of all refrigerant-side diagnostics.
Lesson 5 • Refrigerant Recharging Techniques
Covers weighing-in, superheat, and subcooling methods for accurate refrigerant charging. Correct refrigerant charge levels restore rated capacity and prevent compressor damage.
Chapter 7HideHide detailsSee detailsElectrical System Diagnostics and Testing
Electrical System Diagnostics and Testing
Lesson 1 • Testing Capacitors and Contactors
Measures capacitance, checks contactor contacts, and identifies failed components with a multimeter. Capacitor and contactor faults are amongst the most common AC electrical failures.
Lesson 2 • Wiring Inspection and Repair
Identifies damaged insulation, loose terminals, and corroded connections in line and control wiring. Sound wiring prevents intermittent faults and fire hazards.
Lesson 3 • Systematic Fault Isolation Workflow
Applies a structured divide-and-test approach to narrow faults from symptom to root cause. A repeatable workflow reduces diagnostic time and prevents misdiagnosis.
Lesson 4 • Motor Winding Resistance Testing
Tests compressor and fan motor windings for opens, shorts, and ground faults. Winding tests confirm motor health before and after cleaning or refrigerant work.
Lesson 5 • Control Board and Sensor Testing
Checks thermistor resistance, voltage outputs, and relay operation on indoor and outdoor boards. Board-level diagnostics prevent unnecessary component replacement.
Chapter 8HideHide detailsSee detailsPreventive Maintenance Scheduling and Reporting
Preventive Maintenance Scheduling and Reporting
Lesson 1 • Performance Benchmarking
Records temperature differentials, current draw, and coil pressures as baseline performance data. Benchmarks enable early detection of degradation between scheduled service visits.
Lesson 2 • Preventive Maintenance Checklists
Builds task-specific checklists covering all indoor, outdoor, and refrigerant-side inspection points. Checklists ensure consistent service quality across different technicians and sites.
Lesson 3 • Service Report Writing
Structures professional reports with findings, actions taken, parts used, and follow-up recommendations. Clear reports protect technicians legally and inform client decisions.
Lesson 4 • Client Communication and Handover
Explains service outcomes, filter care, and warning signs to clients in plain language. Effective handover builds client trust and reduces unnecessary callback visits.
Lesson 5 • Maintenance Interval Planning
Determines cleaning and inspection frequencies based on environment, usage, and manufacturer guidance. Correct intervals prevent premature failures and unnecessary service costs.
Your valid completion certificate
This course is for you:
HVAC apprentices: ready to specialise in split AC service work.
General handymen: expanding into climate control maintenance for extra income.
Facilities technicians: responsible for keeping commercial AC units running reliably.
Career changers: entering the trades with no prior refrigeration background.
Property managers: wanting to understand what contractors should actually be doing.
Small business owners: building an AC maintenance service from the ground up.
Related Courses
FAQ
Who is Dedika?
Is the certificate valid in Australia?
Are the courses free?
What is the course workload?
What are the courses like?
How do the courses work?
What is the duration of the courses?
What is the cost or price of the courses?
What is an EAD or online course and how does it work?
PDF Course