Electrical Protection Systems Course
Master the full scope of electrical protection systems, from instrument transformers and overcurrent coordination to distance relays, differential schemes, and teleprotection. This course gives protection engineers and power system professionals the technical depth to design, set, commission, and maintain protection systems that keep power networks safe and reliable.
What your team will master:
You will build a complete understanding of protection system fundamentals, including fault types, protection zones, and coordination principles. You will learn to select and test current and voltage transformers, calculate relay settings for overcurrent and distance protection, and configure differential schemes for transformers, busbars, and generators. The course also covers communication-aided protection, IEC 61850 architecture, and renewable energy protection challenges. You will develop hands-on commissioning and maintenance skills backed by structured test procedures and record management practices.
How your team learns practically Electrical Protection Systems Course
How your team practises Electrical Protection Systems Course
Professionals from these companies study at Dedika









Course content
8 Chapters • 38 LessonsDuration between 4 and 360 hours (you decide)
Chapter 1HideHide detailsSee detailsFundamentals of Electrical Protection
Fundamentals of Electrical Protection
Lesson 1 • Protection System Objectives
Defines reliability, selectivity, speed, and sensitivity as core protection goals. Links each objective to real-world fault scenarios and equipment safety.
Lesson 2 • Protection Zones and Coordination Concepts
Explains overlapping protection zones and the principle of primary versus backup protection. Prepares learners for coordination studies in later chapters.
Lesson 3 • Power System Basics and Threats
Introduces voltage levels, current flow, and common fault types in power systems. Establishes the threat landscape that protection systems must address.
Lesson 4 • Protection System Components Overview
Surveys instrument transformers, relays, circuit breakers, and communication links. Provides a system-level view before detailed component study begins.
Chapter 2HideHide detailsSee detailsInstrument Transformers and Measurement
Instrument Transformers and Measurement
Lesson 1 • Instrument Transformer Testing and Maintenance
Presents ratio tests, polarity checks, insulation resistance, and burden measurements. Routine testing confirms transformer integrity before relay commissioning.
Lesson 2 • Current Transformer Principles
Covers CT construction, magnetising characteristics, and burden effects on accuracy. Accurate CT selection is critical for reliable relay operation.
Lesson 3 • Voltage Transformer Principles
Examines electromagnetic and capacitive VT designs, ratio errors, and phase displacement. Correct VT selection ensures accurate voltage measurement for relays.
Lesson 4 • CT and VT Connection Schemes
Details star, delta, and open-delta wiring configurations for three phase systems. Proper connections determine which fault types relays can detect.
Chapter 3HideHide detailsSee detailsOvercurrent and Earth Fault Protection
Overcurrent and Earth Fault Protection
Lesson 1 • Coordination Studies and Grading
Applies grading margins, relay curves, and fuse-relay coordination to build a complete protection scheme. Students produce and verify time-current coordination plots.
Lesson 2 • Directional Overcurrent Protection
Introduces directional elements for ring mains and parallel feeders where fault current can flow in both directions. Polarising methods and connection angles are explained.
Lesson 3 • Pickup and Time Dial Setting Methods
Teaches load current analysis, fault current calculation, and margin selection for pickup settings. Time dial settings are derived to achieve selective tripping.
Lesson 4 • Earth Fault Relay Applications
Covers residual current detection, zero-sequence filtering, and high-resistance earth fault methods. Earth fault settings differ from phase overcurrent due to lower fault currents.
Lesson 5 • Overcurrent Relay Characteristics
Explains definite-time, inverse-time, and instantaneous relay operating curves. Understanding curve shapes is prerequisite to coordination calculations.
Chapter 4HideHide detailsSee detailsDistance Protection Principles and Settings
Distance Protection Principles and Settings
Lesson 1 • Distance Relay Testing and Commissioning
Covers secondary injection testing, characteristic verification, and on-load checks for distance relays. Commissioning confirms that settings match the protection design intent.
Lesson 2 • Zone Reach and Time Setting
Derives Zone 1, 2, and 3 reach settings based on line impedance and infeed effects. Time delays for each zone ensure selectivity without sacrificing speed.
Lesson 3 • Distance Protection for Special Conditions
Addresses series compensation, mutual coupling, and power swing blocking for complex line configurations. These conditions require setting adjustments beyond standard zone calculations.
Lesson 4 • Impedance Measurement Fundamentals
Explains how relays measure apparent impedance from voltage and current inputs. This measurement principle underpins all distance relay operating characteristics.
Lesson 5 • Distance Relay Characteristics
Compares mho, quadrilateral, and lens characteristics on the R-X diagram. Characteristic shape determines coverage of resistive faults and load avoidance.
Chapter 5HideHide detailsSee detailsDifferential Protection Systems
Differential Protection Systems
Lesson 1 • Differential Protection Principles
Explains Kirchhoff's current law as the basis for differential protection and defines operate and restraint quantities. This principle applies to all differential relay types.
Lesson 2 • Differential Scheme Testing and Troubleshooting
Presents primary injection, secondary injection, and stability tests for differential schemes. Troubleshooting guides students through spurious trip and failure-to-operate analysis.
Lesson 3 • Generator and Motor Differential Protection
Applies differential protection to rotating machines, including split-phase and stator winding schemes. Machine differential settings account for CT location and winding configuration.
Lesson 4 • Transformer Differential Protection
Addresses CT ratio matching, vector group compensation, and inrush restraint for power transformers. Correct compensation prevents false trips during energisation.
Lesson 5 • Busbar Differential Protection
Covers high-impedance and low-impedance busbar differential schemes and their CT requirements. Busbar protection must operate fast to limit fault damage and system instability.
Chapter 6HideHide detailsSee detailsGenerator and Transformer Protection
Generator and Transformer Protection
Lesson 1 • Generator Abnormal Condition Protection
Covers under-frequency, overexcitation, and pole slipping protection for generators under abnormal system conditions. Settings must balance machine protection with system support requirements.
Lesson 2 • Scheme Integration and Single-Line Design
Integrates all protection functions into a coordinated scheme shown on a protection single-line diagram. Students verify coverage, redundancy, and correct relay function allocation.
Lesson 3 • Power Transformer Protection Functions
Details overcurrent, earth fault, overfluxing, and thermal protection applied to power transformers. Each function complements differential protection to cover all failure modes.
Lesson 4 • Generator Protection Functions
Surveys loss of excitation, loss of mains, reverse power, and stator earth fault protection functions. Each function targets a specific machine failure mode.
Lesson 5 • Unit Transformer and Auxiliary Protection
Addresses protection for unit transformers, station service transformers, and auxiliary busbars. Auxiliary system faults can cascade to affect generating unit availability.
Chapter 7HideHide detailsSee detailsProtection Communication and Teleprotection
Protection Communication and Teleprotection
Lesson 1 • Direct Transfer Trip Schemes
Covers intertripping applications for transformer faults, breaker failure, and remote end isolation. Direct transfer trip requires high-security channels to prevent unwanted tripping.
Lesson 2 • Teleprotection Scheme Testing
Presents end-to-end testing procedures for communication-aided schemes using secondary injection and loopback methods. Test results confirm correct logic and channel performance.
Lesson 3 • Current Differential Line Protection
Applies pilot differential protection using digital communication for high-speed line protection. Synchronisation and channel delay compensation are key design considerations.
Lesson 4 • Permissive and Blocking Schemes
Explains PUTT, POTT, and directional comparison blocking logic for distance and directional relays. Scheme selection depends on channel reliability and fault clearance speed requirements.
Lesson 5 • Communication Channels for Protection
Compares power line carrier, fibre optic, microwave, and pilot wire channels for protection signalling. Channel characteristics determine scheme performance and reliability.
Chapter 8HideHide detailsSee detailsProtection System Commissioning and Maintenance
Protection System Commissioning and Maintenance
Lesson 1 • Commissioning Planning and Safety
Covers pre-commissioning checks, isolation procedures, and safety documentation for live substation environments. Safe working practices are mandatory before any relay testing begins.
Lesson 2 • Relay Functional Testing Methods
Details secondary injection, characteristic testing, and timing verification for numerical and electromechanical relays. Functional tests confirm relay settings match the approved protection design.
Lesson 3 • Maintenance Strategies and Intervals
Compares time-based, condition-based, and reliability-centred maintenance strategies for protection equipment. Maintenance intervals are justified by equipment criticality and failure data.
Lesson 4 • Protection Records and Change Management
Establishes requirements for relay setting records, as-built drawings, and modification control. Accurate records prevent miscoordination when system changes are made.
Lesson 5 • Trip Circuit and Breaker Testing
Verifies trip coil continuity, circuit breaker operating times, and auxiliary contact performance. Trip circuit integrity is essential for protection system dependability.
Your valid completion certificate
This course is for you:
Protection engineer: needs structured depth to move beyond workplace training trial and error.
Power systems engineer: wants to add relay setting and coordination to their skill set.
Substation commissioning technician: ready to understand the engineering behind the tests performed.
Electrical engineering graduate: entering the power industry and building a protection specialisation.
Maintenance engineer: responsible for relay testing but lacking formal protection theory background.
Career changer from general electrical work: transitioning into utility or transmission system roles.
Related Courses
FAQ
Who is Dedika?
Is the certificate valid in Nigeria?
Are the courses free?
What is the course workload?
What are the courses like?
How do the courses work?
What is the duration of the courses?
What is the cost or price of the courses?
What is an EAD or online course and how does it work?
PDF Course